PLATES & GASKETS

Gasket Selection.

Provide the following information to our THS sales team for a quote at This email address is being protected from spambots. You need JavaScript enabled to view it. or 905-831-4963.
  • 1.
    Manufacturer
  • 2.
  • 3.
    Application (Water, Steam, Glycol)
  • 5.
  • 6.
    Quantity
  • 7.
    Type
  • 8.
    Nameplate Image

Model Finder

  1. Measure the center to center mm of the port holes horizontal (A) and vertical (B)
    along with the length (C), width (D) and port ring diameter (E).

  2. Choose Manufacturer for model chart 

Schmidt-Bretten plate heat exchangers

Schmidt-Bretten plate heat exchangers

Model
type
Sigma
S 7
Sigma
S 9
Sigma
S 12
Sigma
S 16
Sigma
S 17
Sigma
S 27
A = mm 90 90     110 174
B = mm 480 704     868 980
             
Model
type
Sigma
S 27 clip
Sigma
S 20
Sigma
S 22
Sigma
S 26 snap
Sigma
S 32
Sigma
S 37
A = mm 174 178 178 174 230 218
B = mm 980 860 860 980 1056 1076
             
Model
type
Sigma
S 37 clip
Sigma
S 47
Sigma
S 52
Sigma
S 64
Sigma
S 65
Sigma
S 65 clip
A = mm 218   314 290 290 290
B = mm 1076   1252 1471 1471 1471
             
Model
type
Sigma
S 66 snap
Sigma
S 85
Sigma
S 108
Sigma
S 114
Sigma
S 138
Sigma
S 149 snap
A = mm 290 290 425 425 425 560
B = mm 1471 1928 1675 1675 2081 1835
             
Model
type
Sigma
S 156 snap
Sigma
Star 45
Sigma
Star 90
Sigma
Star 55v
Sigma
Star 32-35v
 
A = mm 260       225  
B = mm 1835       1050  

Material

Selecting the wrong gasket can be a timely and costly mistake. Let our experienced THS sales team recommend the most durable and cost effective gasket material for your application by providing us with the pressure, temperature and process liquid details.

Buna (NBR/Nitrile), EPDM or Viton materials are the most common plate & frame heat exchanger gaskets depending on the operating application.

Food Grade
Standard Grade
Aggressive Chemical Compounds

Changes in Gaskets:

  • Time – Relaxes
  • Temperature – Deteriorates
  • Oxidizing Agents – Hardens
  • Swelling – Chemical Absorption

Gaskets Material Depends on:

  • Fluids Used
  • Temperature and Pressure

Standard Gasket Styles

Clip - will usually have rubber tabs that are visible from the outside of the heat exchanger

Glue – no tabs and in most cases the brown glue is visible under the gasket; typically used in high pressure or high temperature applications

Ball - used in HVAC or FDA applications to allow for easy removal in the field 

HEAD OFFICE

1550 Bayly Street, Unit 15
Pickering, ON L1W 3W1

T 905 831-4963
F 905 831-0042

SERVICE CENTER

76 Harlowe Road, Unit 5, 6 & 7
Hamilton, ON L8W 3R6

T 905 318-0777
F 905-318-8422