PLATES & GASKETS

Gasket Selection.

Provide the following information to our THS sales team for a quote at This email address is being protected from spambots. You need JavaScript enabled to view it. or 905-831-4963.
  • 1.
    Manufacturer
  • 2.
  • 3.
    Application (Water, Steam, Glycol)
  • 5.
  • 6.
    Quantity
  • 7.
    Type
  • 8.
    Nameplate Image

Model Finder

  1. Measure the center to center mm of the port holes horizontal (A) and vertical (B)
    along with the length (C), width (D) and port ring diameter (E).

  2. Choose Manufacturer for model chart 

Hisaka Gaskets

Hisaka Gaskets

Model UX 005 UX 01 UX 10
UX 11 / 22
UX 20
UX 21 / 22
UX 30
UX 31 / 32
UX 40
UX 41 / 42
A = mm 160 300 390 550 610 760
B = mm 331 850 1080 1540 1891.5 2135
             
Model UX 80 UX 90
UX 91 / 92
UX 100
102-103-104
EX 11 EX 15 SX 40
SX 43 / 45
A = mm   1300 1570 760 550 805
B = mm   2829 3590 + 2100 1445 2165
             
Model SX 41/ 44 SX 70
SX 71 / 74
RX 00
RX 01 / 02
RX 10
RX 13 / 14
RX 30
RX 31 / 32
RX 70
RX 71 / 72
A = mm 805 1070 242 450 650 985
B = mm 2165 2692 488 1080 1850 2490 +
             
Model LX 00
LX 01 / 02
LX 10
LX 11 / 12
LX 20
LX 21 / 22
LX 30
LX 31 / 32
LX 40
LX 41 / 42
LX 50
LX 51 / 52
A = mm 350 460 580 650 790 810
B = mm 787 1066 1593 1575-1675 2075 1995

Material

Selecting the wrong gasket can be a timely and costly mistake. Let our experienced THS sales team recommend the most durable and cost effective gasket material for your application by providing us with the pressure, temperature and process liquid details.

Buna (NBR/Nitrile), EPDM or Viton materials are the most common plate & frame heat exchanger gaskets depending on the operating application.

Food Grade
Standard Grade
Aggressive Chemical Compounds

Changes in Gaskets:

  • Time – Relaxes
  • Temperature – Deteriorates
  • Oxidizing Agents – Hardens
  • Swelling – Chemical Absorption

Gaskets Material Depends on:

  • Fluids Used
  • Temperature and Pressure

Standard Gasket Styles

Clip - will usually have rubber tabs that are visible from the outside of the heat exchanger

Glue – no tabs and in most cases the brown glue is visible under the gasket; typically used in high pressure or high temperature applications

Ball - used in HVAC or FDA applications to allow for easy removal in the field 

HEAD OFFICE

1550 Bayly Street, Unit 15
Pickering, ON L1W 3W1

T 905 831-4963
F 905 831-0042

SERVICE CENTER

76 Harlowe Road, Unit 5, 6 & 7
Hamilton, ON L8W 3R6

T 905 318-0777
F 905-318-8422